{"id":2271,"date":"2020-10-01T12:21:23","date_gmt":"2020-10-01T10:21:23","guid":{"rendered":"http:\/\/cmp.krohne.com\/analyse\/?page_id=2271"},"modified":"2026-03-23T11:25:32","modified_gmt":"2026-03-23T10:25:32","slug":"conductivity","status":"publish","type":"page","link":"https:\/\/cmp.krohne.com\/analytics\/conductivity\/","title":{"rendered":"KROHNE Process Analytics \u2013 Conductivity"},"content":{"rendered":"\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-2072kf-4e01f3344a2f33efe18e8983dc6b9fd2\">\n#top .av-special-heading.av-2072kf-4e01f3344a2f33efe18e8983dc6b9fd2{\npadding-bottom:10px;\n}\nbody .av-special-heading.av-2072kf-4e01f3344a2f33efe18e8983dc6b9fd2 .av-special-heading-tag .heading-char{\nfont-size:25px;\n}\n.av-special-heading.av-2072kf-4e01f3344a2f33efe18e8983dc6b9fd2 .av-subheading{\nfont-size:15px;\n}\n<\/style>\n<div  class='av-special-heading av-2072kf-4e01f3344a2f33efe18e8983dc6b9fd2 av-special-heading-h1 blockquote modern-quote  avia-builder-el-0  el_before_av_textblock  avia-builder-el-first '><div class='av-subheading av-subheading_above'><p>Conductivity<\/p>\n<\/div><h1 class='av-special-heading-tag'  itemprop=\"headline\"  >Define your specifications<\/h1><div class=\"special-heading-border\"><div class=\"special-heading-inner-border\"><\/div><\/div><\/div>\n<section  class='av_textblock_section av-4my20-85cd48aa5acc66c5355d27a098c8c69a '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><div class=\"filter-produkte-container\"><div class=\"filter-container\"><div class=\"filter-set filter-set-group\"><h6 class=\"filter-set__title\">Conductivity range<\/h6><a class=\"filter_on-off disabled\" href=\"\"><span>on<\/span><b><\/b><span>off<\/span><\/a><div class=\"filter\"><a class='filter_button radio' data-filter='f6' data-connection='' href=''><10 \u00b5S\/cm<span><\/span><\/a><a class='filter_button radio' data-filter='f7' data-connection='' href=''>10-100 \u00b5S\/cm<span><\/span><\/a><a class='filter_button radio' data-filter='f8' data-connection='' href=''>100-1000 \u00b5S\/cm<span><\/span><\/a><a class='filter_button radio' data-filter='f9' data-connection='' href=''>1-20 mS\/cm<span><\/span><\/a><a class='filter_button radio' data-filter='f10' data-connection='' href=''>>20 mS\/cm<span><\/span><\/a><\/div><\/div><div class=\"filter-set filter-set-group\"><h6 class=\"filter-set__title\">Temperature<\/h6><a class=\"filter_on-off disabled\" href=\"\"><span>on<\/span><b><\/b><span>off<\/span><\/a><div class=\"filter\"><a class='filter_button radio' data-filter='f11' data-connection='' href=''><60\u00b0C<span><\/span><\/a><a class='filter_button radio' data-filter='f12' data-connection='' href=''><90\u00b0C<span><\/span><\/a><a class='filter_button radio' data-filter='f13' data-connection='' href=''><135\u00b0C<span><\/span><\/a><a class='filter_button radio' data-filter='f14' data-connection='' href=''><200\u00b0C<span><\/span><\/a><\/div><\/div><div class=\"filter-set filter-set-group\"><h6 class=\"filter-set__title\">Pressure<\/h6><a class=\"filter_on-off disabled\" href=\"\"><span>on<\/span><b><\/b><span>off<\/span><\/a><div class=\"filter\"><a class='filter_button radio' data-filter='f15' data-connection='' href=''><10 bar<span><\/span><\/a><a class='filter_button radio' data-filter='f16' data-connection='' href=''><16 bar<span><\/span><\/a><a class='filter_button radio' data-filter='f17' data-connection='' href=''><40 bar<span><\/span><\/a><\/div><\/div><div class=\"filter-set-group\"><h6 class=\"filter-set__title\">Installation<\/h6><a class=\"filter_on-off disabled\" href=\"\"><span>on<\/span><b><\/b><span>off<\/span><\/a><div class=\"filter-set\"><div class=\"filter\"><a class='filter_button check' data-filter='f18' data-connection='' href=''>Immersion<span><\/span><\/a><\/div><\/div><div class=\"filter-set\"><div class=\"filter\"><a class='filter_button check' data-filter='f19' data-connection='' href=''>Insertion<span><\/span><\/a><\/div><\/div><\/div><div class=\"filter-set filter-set-group\"><h6 class=\"filter-set__title\">Sensor or system<\/h6><a class=\"filter_on-off disabled\" href=\"\"><span>on<\/span><b><\/b><span>off<\/span><\/a><div class=\"filter\"><a class='filter_button radio' data-filter='f20' data-connection='Direct communication via 4...20 mA\/HART\u00ae 7' href=''>analog sensor only<div class='filter_tooltip'>It produces continuous output that can be voltage or current which is proportional to defined measured quantity.<\/div><span><\/span><\/a><a class='filter_button radio' data-filter='f21' data-connection='Direct communication via 4...20 mA\/HART\u00ae7' href=''>sensor with integral transmitter<div class='filter_tooltip'>This sensor has integrated transmitter. It has fieldbus communication and current output. It can be connected directly to the process control system. It saves all measurement data and transfer it digitally (non-continuous or discrete form of signal) via via HART protocol to Process control system, PCs.<\/div><span><\/span><\/a><a class='filter_button radio' data-filter='f22' data-connection='Complete system with sensor and analytical transmitter' href=''>complete system<span><\/span><\/a><\/div><\/div><\/div><div class=\"reset-container off\"><div class=\"reset-container__left\"><span class=\"produkte__anzahl\"><i>0<\/i> suitable product<span class=\"plural\">s<\/span> for the measurement of conductivity<\/span><span class=\"produkte__connection\"><\/span><br><span class=\"produkte__fussnote\">Lower conductivity ranges are not included! Deviations from max. temp \/ pressure are possible. Please contact us for further information.<\/span><\/div><a class=\"reset-button\">Reset filters<\/a><\/div><div class=\"produkte\"><div class=\"no_result off\"><h3>Ihre Auswahl ergab leider keine Treffer<\/h3><\/div><ul class=\"produkte__liste\"><li class='produkt f8 f9 f11 f12 f13 f15 f16 f19 f21'><div class='produkt__inside'><div><figure class='produkt__bild'><img src='https:\/\/dam.krohne.com\/image\/upload\/c_scale,w_900\/im-single-product\/smartpat-cond-1200.png' alt='SMARTPAT COND 1200'><\/figure><div class='produkt__text'><h3 class='produkt__name'>SMARTPAT COND 1200<\/h3><p>Water and wastewater applications<\/p><div class='produkt__features'><ul><li>0.1\u202620 mS\/cm; Max. +135\u00b0C \/ +275\u00b0F; 16 bar \/ 232 psi<\/li><li>Rugged 2-electrode conductivity sensor with stainless steel electrodes and Pt1000 <\/li><\/ul><\/div><a href=\"#\" class=\"produkt__button-request avia-button avia-icon_select-yes-right-icon avia-color-theme-color avia-size-medium avia-position-left\" style=\"background-color:#e94d19;\"><span class=\"avia_iconbox_title\">Send your request<\/span><span class=\"avia_button_icon avia_button_icon_right\" aria-hidden=\"true\" data-av_icon=\"\ue875\" data-av_iconfont=\"entypo-fontello\"><\/span><\/a><br><a href=\"https:\/\/krohne.com\/en\/products\/process-analytics\/analytical-sensors-measuring-systems\/conductivity-sensors-measuring-systems\/smartpat-cond-1200\/\" target=\"_blank\" class=\"produkt__button-produkt avia-button avia-icon_select-yes-right-icon avia-color-theme-color avia-size-medium avia-position-left\" rel=\"noopener\"><span class=\"avia_iconbox_title\">View product<\/span><span class=\"avia_button_icon avia_button_icon_right\" aria-hidden=\"true\" data-av_icon=\"\ue875\" data-av_iconfont=\"entypo-fontello\"><\/span><\/a><\/div><\/div><\/div><\/li><li class='produkt f6 f7 f8 f11 f12 f13 f15 f16 f18 f19 f21'><div class='produkt__inside'><div><figure class='produkt__bild'><img src='https:\/\/dam.krohne.com\/image\/upload\/c_scale,w_900\/im-single-product\/smartpat-cond-3200.png' alt='SMARTPAT COND 3200'><\/figure><div class='produkt__text'><h3 class='produkt__name'>SMARTPAT COND 3200<\/h3><p>Condensate, process, boiler feed or (ultra) pure water<\/p><div class='produkt__features'><ul><li>0.05\u20261000 \u03bcS\/cm; Max. +135\u00b0C \/ +275\u00b0F; 16 bar \/ 232 psi<\/li><li>2-electrode conductivity sensor with stainless steel electrodes and Pt1000<\/li><\/ul><\/div><a href=\"#\" class=\"produkt__button-request avia-button avia-icon_select-yes-right-icon avia-color-theme-color avia-size-medium avia-position-left\" style=\"background-color:#e94d19;\"><span class=\"avia_iconbox_title\">Send your request<\/span><span class=\"avia_button_icon avia_button_icon_right\" aria-hidden=\"true\" data-av_icon=\"\ue875\" data-av_iconfont=\"entypo-fontello\"><\/span><\/a><br><a href=\"https:\/\/krohne.com\/en\/products\/process-analytics\/analytical-sensors-measuring-systems\/conductivity-sensors-measuring-systems\/smartpat-cond-3200\/\" target=\"_blank\" class=\"produkt__button-produkt avia-button avia-icon_select-yes-right-icon avia-color-theme-color avia-size-medium avia-position-left\" rel=\"noopener\"><span class=\"avia_iconbox_title\">View product<\/span><span class=\"avia_button_icon avia_button_icon_right\" aria-hidden=\"true\" data-av_icon=\"\ue875\" data-av_iconfont=\"entypo-fontello\"><\/span><\/a><\/div><\/div><\/div><\/li><li class='produkt f8 f9 f11 f12 f13 f15 f16 f18 f19 f21 f25'><div class='produkt__inside'><div><figure class='produkt__bild'><img src='https:\/\/dam.krohne.com\/image\/upload\/c_scale,w_900\/im-single-product\/smartpat-cond-5200.png' alt='SMARTPAT COND 5200'><small class='produkt__zertifikate'><strong class='produkt__label produkt__label--ex'>Ex<\/strong><\/small><\/figure><div class='produkt__text'><h3 class='produkt__name'>SMARTPAT COND 5200<\/h3><p>Chemicals and industrial wastewater applications<\/p><div class='produkt__features'><ul><li>10 \u00b5S\u202615 mS\/cm; Max. +130\u00b0C \/ +266\u00b0F; 16 bar \/ 232 psi<\/li><li>Corrosion resistant 2-electrode conductivity sensor width graphite electrodes and Pt1000<\/li><\/ul><\/div><a href=\"#\" class=\"produkt__button-request avia-button avia-icon_select-yes-right-icon avia-color-theme-color avia-size-medium avia-position-left\" style=\"background-color:#e94d19;\"><span class=\"avia_iconbox_title\">Send your request<\/span><span class=\"avia_button_icon avia_button_icon_right\" aria-hidden=\"true\" data-av_icon=\"\ue875\" data-av_iconfont=\"entypo-fontello\"><\/span><\/a><br><a href=\"https:\/\/krohne.com\/en\/products\/process-analytics\/analytical-sensors-measuring-systems\/conductivity-sensors-measuring-systems\/smartpat-cond-5200\/\" target=\"_blank\" class=\"produkt__button-produkt avia-button avia-icon_select-yes-right-icon avia-color-theme-color avia-size-medium avia-position-left\" rel=\"noopener\"><span class=\"avia_iconbox_title\">View product<\/span><span class=\"avia_button_icon avia_button_icon_right\" aria-hidden=\"true\" data-av_icon=\"\ue875\" data-av_iconfont=\"entypo-fontello\"><\/span><\/a><\/div><\/div><\/div><\/li><li class='produkt f6 f7 f8 f11 f12 f13 f15 f16 f19 f21 f23'><div class='produkt__inside'><div><figure class='produkt__bild'><img src='https:\/\/dam.krohne.com\/image\/upload\/c_scale,w_900\/im-single-product\/smartpat-cond-7200.png' alt='SMARTPAT COND 7200'><small class='produkt__zertifikate'><strong class='produkt__label produkt__label--hygienic'>Hygienic (FDA)<\/strong><\/small><\/figure><div class='produkt__text'><h3 class='produkt__name'>SMARTPAT COND 7200<\/h3><p>Food, beverage and pharmaceutical applications<\/p><div class='produkt__features'><ul><li>0.05\u20261000 \u03bcS\/cm; Max. +135\u00b0C \/ +275\u00b0F; 16 bar \/ 232 psi<\/li><li>Hygienic 2-electrode conductivity sensor with stainless steel electrodes (Ra&lt;0.8\u03bcm) and Pt1000 <\/li><\/ul><\/div><a href=\"#\" class=\"produkt__button-request avia-button avia-icon_select-yes-right-icon avia-color-theme-color avia-size-medium avia-position-left\" style=\"background-color:#e94d19;\"><span class=\"avia_iconbox_title\">Send your request<\/span><span class=\"avia_button_icon avia_button_icon_right\" aria-hidden=\"true\" data-av_icon=\"\ue875\" data-av_iconfont=\"entypo-fontello\"><\/span><\/a><br><a href=\"https:\/\/krohne.com\/en\/products\/process-analytics\/analytical-sensors-measuring-systems\/conductivity-sensors-measuring-systems\/smartpat-cond-7200\/\" target=\"_blank\" class=\"produkt__button-produkt avia-button avia-icon_select-yes-right-icon avia-color-theme-color avia-size-medium avia-position-left\" rel=\"noopener\"><span class=\"avia_iconbox_title\">View product<\/span><span class=\"avia_button_icon avia_button_icon_right\" aria-hidden=\"true\" data-av_icon=\"\ue875\" data-av_iconfont=\"entypo-fontello\"><\/span><\/a><\/div><\/div><\/div><\/li><li class='produkt f6 f7 f8 f9 f11 f12 f13 f15 f16 f19 f20'><div class='produkt__inside'><div><figure class='produkt__bild'><img src='https:\/\/dam.krohne.com\/image\/upload\/c_scale,w_900\/im-single-product\/optisens-cond-1200-insertion.png' alt='OPTISENS COND 1200'><\/figure><div class='produkt__text'><h3 class='produkt__name'>OPTISENS COND 1200<\/h3><p>Water, pure water and wastewater applications<\/p><div class='produkt__features'><ul><li>0.1 \u03bcS\/cm\u202620 mS\/cm; Max. +135\u00b0C \/ +275\u00b0F; 16 bar \/ 232 psi <\/li><li>Insertion 2-electrode conductivity sensor with stainless steel electrodes, PVDF sensor body and Pt100 <\/li><\/ul><\/div><a href=\"#\" class=\"produkt__button-request avia-button avia-icon_select-yes-right-icon avia-color-theme-color avia-size-medium avia-position-left\" style=\"background-color:#e94d19;\"><span class=\"avia_iconbox_title\">Send your request<\/span><span class=\"avia_button_icon avia_button_icon_right\" aria-hidden=\"true\" data-av_icon=\"\ue875\" data-av_iconfont=\"entypo-fontello\"><\/span><\/a><br><a href=\"https:\/\/krohne.com\/en\/products\/process-analytics\/analytical-sensors-measuring-systems\/conductivity-sensors-measuring-systems\/optisens-cond-1200\/\" target=\"_blank\" class=\"produkt__button-produkt avia-button avia-icon_select-yes-right-icon avia-color-theme-color avia-size-medium avia-position-left\" rel=\"noopener\"><span class=\"avia_iconbox_title\">View product<\/span><span class=\"avia_button_icon avia_button_icon_right\" aria-hidden=\"true\" data-av_icon=\"\ue875\" data-av_iconfont=\"entypo-fontello\"><\/span><\/a><\/div><\/div><\/div><\/li><li class='produkt f7 f8 f9 f11 f12 f15 f18 f20'><div class='produkt__inside'><div><figure class='produkt__bild'><img src='https:\/\/dam.krohne.com\/image\/upload\/c_scale,w_900\/im-single-product\/optisens-cond-1200-immerson.png' alt='OPTISENS COND 1210'><\/figure><div class='produkt__text'><h3 class='produkt__name'>OPTISENS COND 1210<\/h3><p>Water and treated wastewater applications<\/p><div class='produkt__features'><ul><li>1 \u03bcS\/cm\u202620 mS\/cm; Max. +90\u00b0C \/ +194\u00b0F; 16 bar \/ 232 psi<\/li><li>Immersion 2-electrode conductivity sensor with stainless steel electrodes, PP sensor body and Pt100 <\/li><\/ul><\/div><a href=\"#\" class=\"produkt__button-request avia-button avia-icon_select-yes-right-icon avia-color-theme-color avia-size-medium avia-position-left\" style=\"background-color:#e94d19;\"><span class=\"avia_iconbox_title\">Send your request<\/span><span class=\"avia_button_icon avia_button_icon_right\" aria-hidden=\"true\" data-av_icon=\"\ue875\" data-av_iconfont=\"entypo-fontello\"><\/span><\/a><br><a href=\"https:\/\/krohne.com\/en\/products\/process-analytics\/analytical-sensors-measuring-systems\/conductivity-sensors-measuring-systems\/optisens-cond-1200\/\" target=\"_blank\" class=\"produkt__button-produkt avia-button avia-icon_select-yes-right-icon avia-color-theme-color avia-size-medium avia-position-left\" rel=\"noopener\"><span class=\"avia_iconbox_title\">View product<\/span><span class=\"avia_button_icon avia_button_icon_right\" aria-hidden=\"true\" data-av_icon=\"\ue875\" data-av_iconfont=\"entypo-fontello\"><\/span><\/a><\/div><\/div><\/div><\/li><li class='produkt f6 f7 f8 f11 f12 f13 f15 f16 f19 f20'><div class='produkt__inside'><div><figure class='produkt__bild'><img src='https:\/\/dam.krohne.com\/image\/upload\/c_scale,w_900\/im-single-product\/optisens-cond-3200.png' alt='OPTISENS COND 3200'><\/figure><div class='produkt__text'><h3 class='produkt__name'>OPTISENS COND 3200<\/h3><p>Condensate, process, boiler feed or (ultra)pure water<\/p><div class='produkt__features'><ul><li>0.05\u20261000 \u03bcS\/cm; Max. +135\u00b0C \/ +275\u00b0F; 16 bar \/ 232 psi <\/li><li>2-electrode conductivity sensor with stainless steel (1.4571\/316Ti) or titanium electrodes, PVDF or stainless steel (1.4571\/316Ti) sensor body and Pt100<\/li><\/ul><\/div><a href=\"#\" class=\"produkt__button-request avia-button avia-icon_select-yes-right-icon avia-color-theme-color avia-size-medium avia-position-left\" style=\"background-color:#e94d19;\"><span class=\"avia_iconbox_title\">Send your request<\/span><span class=\"avia_button_icon avia_button_icon_right\" aria-hidden=\"true\" data-av_icon=\"\ue875\" data-av_iconfont=\"entypo-fontello\"><\/span><\/a><br><a href=\"https:\/\/krohne.com\/en\/products\/process-analytics\/analytical-sensors-measuring-systems\/conductivity-sensors-measuring-systems\/optisens-cond-1200\/\" target=\"_blank\" class=\"produkt__button-produkt avia-button avia-icon_select-yes-right-icon avia-color-theme-color avia-size-medium avia-position-left\" rel=\"noopener\"><span class=\"avia_iconbox_title\">View product<\/span><span class=\"avia_button_icon avia_button_icon_right\" aria-hidden=\"true\" data-av_icon=\"\ue875\" data-av_iconfont=\"entypo-fontello\"><\/span><\/a><\/div><\/div><\/div><\/li><li class='produkt f6 f7 f8 f11 f12 f13 f14 f15 f16 f17 f19 f20'><div class='produkt__inside'><div><figure class='produkt__bild'><img src='https:\/\/dam.krohne.com\/image\/upload\/c_scale,w_900\/im-single-product\/optisens-cond-3200-ht.png' alt='OPTISENS COND 3220'><\/figure><div class='produkt__text'><h3 class='produkt__name'>OPTISENS COND 3220<\/h3><p>Pure and process water with high temperatures and pressures<\/p><div class='produkt__features'><ul><li>1\u20261000 \u03bcS\/cm; Max. +200\u00b0C \/ +392\u00b0F; 40 bar \/ 580 psi <\/li><li>Rugged 2-electrode conductivity sensor with stainless steel electrodes and sensor body (1.4404\/316L) and Pt100<\/li><\/ul><\/div><a href=\"#\" class=\"produkt__button-request avia-button avia-icon_select-yes-right-icon avia-color-theme-color avia-size-medium avia-position-left\" style=\"background-color:#e94d19;\"><span class=\"avia_iconbox_title\">Send your request<\/span><span class=\"avia_button_icon avia_button_icon_right\" aria-hidden=\"true\" data-av_icon=\"\ue875\" data-av_iconfont=\"entypo-fontello\"><\/span><\/a><br><a href=\"https:\/\/krohne.com\/en\/products\/process-analytics\/analytical-sensors-measuring-systems\/conductivity-sensors-measuring-systems\/optisens-cond-1200\/\" target=\"_blank\" class=\"produkt__button-produkt avia-button avia-icon_select-yes-right-icon avia-color-theme-color avia-size-medium avia-position-left\" rel=\"noopener\"><span class=\"avia_iconbox_title\">View product<\/span><span class=\"avia_button_icon avia_button_icon_right\" aria-hidden=\"true\" data-av_icon=\"\ue875\" data-av_iconfont=\"entypo-fontello\"><\/span><\/a><\/div><\/div><\/div><\/li><li class='produkt f8 f9 f11 f12 f13 f15 f16 f19 f20'><div class='produkt__inside'><div><figure class='produkt__bild'><img src='https:\/\/dam.krohne.com\/image\/upload\/c_scale,w_900\/im-single-product\/optisens-cond-5200.png' alt='OPTISENS COND 5200'><\/figure><div class='produkt__text'><h3 class='produkt__name'>OPTISENS COND 5200<\/h3><p>Industrial water, wastewater and chemical applications<\/p><div class='produkt__features'><ul><li>0.01\u202615 mS\/cm; Max. +130\u00b0C \/ +266\u00b0F; 16 bar \/ 232 psi <\/li><li>Corrosion resistant 2-electrode conductivity sensor with graphite electrodes and Pt100 <\/li><\/ul><\/div><a href=\"#\" class=\"produkt__button-request avia-button avia-icon_select-yes-right-icon avia-color-theme-color avia-size-medium avia-position-left\" style=\"background-color:#e94d19;\"><span class=\"avia_iconbox_title\">Send your request<\/span><span class=\"avia_button_icon avia_button_icon_right\" aria-hidden=\"true\" data-av_icon=\"\ue875\" data-av_iconfont=\"entypo-fontello\"><\/span><\/a><br><a href=\"https:\/\/krohne.com\/en\/products\/process-analytics\/analytical-sensors-measuring-systems\/conductivity-sensors-measuring-systems\/optisens-cond-1200\/\" target=\"_blank\" class=\"produkt__button-produkt avia-button avia-icon_select-yes-right-icon avia-color-theme-color avia-size-medium avia-position-left\" rel=\"noopener\"><span class=\"avia_iconbox_title\">View product<\/span><span class=\"avia_button_icon avia_button_icon_right\" aria-hidden=\"true\" data-av_icon=\"\ue875\" data-av_iconfont=\"entypo-fontello\"><\/span><\/a><\/div><\/div><\/div><\/li><li class='produkt f6 f7 f8 f11 f12 f13 f15 f16 f19 f20 f23'><div class='produkt__inside'><div><figure class='produkt__bild'><img src='https:\/\/dam.krohne.com\/image\/upload\/c_scale,w_900\/im-single-product\/optisens-cond-7200-short.png' alt='OPTISENS COND 7200'><small class='produkt__zertifikate'><strong class='produkt__label produkt__label--hygienic'>Hygienic (FDA)<\/strong><\/small><\/figure><div class='produkt__text'><h3 class='produkt__name'>OPTISENS COND 7200<\/h3><p>Food, beverage and pharmaceutical applications<\/p><div class='produkt__features'><ul><li>0.05\u20261000 \u03bcS\/cm; Max. +135\u00b0C \/ +275\u00b0F; 16 bar \/ 232 psi <\/li><li>Hygienic 2-electrode conductivity sensor with short stainless steel electrodes (Ra&lt;0.8\u00b5m) Pt 100 and 4-pin right angle connector<\/li><\/ul><\/div><a href=\"#\" class=\"produkt__button-request avia-button avia-icon_select-yes-right-icon avia-color-theme-color avia-size-medium avia-position-left\" style=\"background-color:#e94d19;\"><span class=\"avia_iconbox_title\">Send your request<\/span><span class=\"avia_button_icon avia_button_icon_right\" aria-hidden=\"true\" data-av_icon=\"\ue875\" data-av_iconfont=\"entypo-fontello\"><\/span><\/a><br><a href=\"https:\/\/krohne.com\/en\/products\/process-analytics\/analytical-sensors-measuring-systems\/conductivity-sensors-measuring-systems\/optisens-cond-7200\/\" target=\"_blank\" class=\"produkt__button-produkt avia-button avia-icon_select-yes-right-icon avia-color-theme-color avia-size-medium avia-position-left\" rel=\"noopener\"><span class=\"avia_iconbox_title\">View product<\/span><span class=\"avia_button_icon avia_button_icon_right\" aria-hidden=\"true\" data-av_icon=\"\ue875\" data-av_iconfont=\"entypo-fontello\"><\/span><\/a><\/div><\/div><\/div><\/li><li class='produkt f6 f7 f8 f11 f12 f13 f15 f16 f19 f20 f23'><div class='produkt__inside'><div><figure class='produkt__bild'><img src='https:\/\/cmp.krohne.com\/analytics\/optisens-cond-7200-long\/' alt='OPTISENS COND 7230'><small class='produkt__zertifikate'><strong class='produkt__label produkt__label--hygienic'>Hygienic (FDA)<\/strong><\/small><\/figure><div class='produkt__text'><h3 class='produkt__name'>OPTISENS COND 7230<\/h3><p>Food, beverage and pharmaceutical applications<\/p><div class='produkt__features'><ul><li>0.05\u20261000 \u03bcS\/cm; Max. +135\u00b0C \/ +275\u00b0F; 16 bar \/ 232 psi <\/li><li>Hygienic 2-electrode conductivity sensor with slim stainless steel electrodes (Ra&lt;0.8\u00b5m), Pt100 and M12 connector<\/li><\/ul><\/div><a href=\"#\" class=\"produkt__button-request avia-button avia-icon_select-yes-right-icon avia-color-theme-color avia-size-medium avia-position-left\" style=\"background-color:#e94d19;\"><span class=\"avia_iconbox_title\">Send your request<\/span><span class=\"avia_button_icon avia_button_icon_right\" aria-hidden=\"true\" data-av_icon=\"\ue875\" data-av_iconfont=\"entypo-fontello\"><\/span><\/a><br><a href=\"https:\/\/krohne.com\/en\/products\/process-analytics\/analytical-sensors-measuring-systems\/conductivity-sensors-measuring-systems\/optisens-cond-1200\/\" target=\"_blank\" class=\"produkt__button-produkt avia-button avia-icon_select-yes-right-icon avia-color-theme-color avia-size-medium avia-position-left\" rel=\"noopener\"><span class=\"avia_iconbox_title\">View product<\/span><span class=\"avia_button_icon avia_button_icon_right\" aria-hidden=\"true\" data-av_icon=\"\ue875\" data-av_iconfont=\"entypo-fontello\"><\/span><\/a><\/div><\/div><\/div><\/li><li class='produkt f9 f10 f11 f15 f19 f20'><div class='produkt__inside'><div><figure class='produkt__bild'><img src='https:\/\/dam.krohne.com\/image\/upload\/c_scale,w_900\/im-single-product\/optisens-ind-1000-pp-insertion.png' alt='OPTISENS IND 1000 PP INS'><\/figure><div class='produkt__text'><h3 class='produkt__name'>OPTISENS IND 1000 PP INS<\/h3><p>Water, wastewater and chemical applications for insertion installation<\/p><div class='produkt__features'><ul><li>1\u20262000 mS\/cm; Max. +60\u00b0C \/ +140\u00b0F; 10 bar \/ 145 psi<\/li><li>Inductive conductivity sensor (PP) with PVC or SS cap nut and Pt1000 <\/li><\/ul><\/div><a href=\"#\" class=\"produkt__button-request avia-button avia-icon_select-yes-right-icon avia-color-theme-color avia-size-medium avia-position-left\" style=\"background-color:#e94d19;\"><span class=\"avia_iconbox_title\">Send your request<\/span><span class=\"avia_button_icon avia_button_icon_right\" aria-hidden=\"true\" data-av_icon=\"\ue875\" data-av_iconfont=\"entypo-fontello\"><\/span><\/a><br><a href=\"https:\/\/krohne.com\/en\/products\/process-analytics\/analytical-sensors-measuring-systems\/conductivity-sensors-measuring-systems\/optisens-ind-1000\/\" target=\"_blank\" class=\"produkt__button-produkt avia-button avia-icon_select-yes-right-icon avia-color-theme-color avia-size-medium avia-position-left\" rel=\"noopener\"><span class=\"avia_iconbox_title\">View product<\/span><span class=\"avia_button_icon avia_button_icon_right\" aria-hidden=\"true\" data-av_icon=\"\ue875\" data-av_iconfont=\"entypo-fontello\"><\/span><\/a><\/div><\/div><\/div><\/li><li class='produkt f9 f10 f11 f12 f15 f19 f20'><div class='produkt__inside'><div><figure class='produkt__bild'><img src='https:\/\/dam.krohne.com\/image\/upload\/c_scale,w_900\/im-single-product\/optisens-ind-1000-pvdf-insertion.png' alt='OPTISENS IND 1000 PVDF INS'><\/figure><div class='produkt__text'><h3 class='produkt__name'>OPTISENS IND 1000 PVDF INS<\/h3><p>Water, wastewater and chemical applications for insertion installation<\/p><div class='produkt__features'><ul><li>1\u20262000 mS\/cm; Max. +100\u00b0C \/ +212\u00b0F; 10 bar \/ 145 psi<\/li><li>Inductive conductivity sensor (PVDF) with PVC or SS cap nut and Pt1000 <\/li><\/ul><\/div><a href=\"#\" class=\"produkt__button-request avia-button avia-icon_select-yes-right-icon avia-color-theme-color avia-size-medium avia-position-left\" style=\"background-color:#e94d19;\"><span class=\"avia_iconbox_title\">Send your request<\/span><span class=\"avia_button_icon avia_button_icon_right\" aria-hidden=\"true\" data-av_icon=\"\ue875\" data-av_iconfont=\"entypo-fontello\"><\/span><\/a><br><a href=\"https:\/\/krohne.com\/en\/products\/process-analytics\/analytical-sensors-measuring-systems\/conductivity-sensors-measuring-systems\/optisens-ind-1000\/\" target=\"_blank\" class=\"produkt__button-produkt avia-button avia-icon_select-yes-right-icon avia-color-theme-color avia-size-medium avia-position-left\" rel=\"noopener\"><span class=\"avia_iconbox_title\">View product<\/span><span class=\"avia_button_icon avia_button_icon_right\" aria-hidden=\"true\" data-av_icon=\"\ue875\" data-av_iconfont=\"entypo-fontello\"><\/span><\/a><\/div><\/div><\/div><\/li><li class='produkt f9 f10 f11 f15 f18 f20'><div class='produkt__inside'><div><figure class='produkt__bild'><img src='https:\/\/dam.krohne.com\/image\/upload\/c_scale,w_900\/im-single-product\/optisens-ind-1000-pp-immersion.png' alt='OPTISENS IND 1000 PP IMM'><\/figure><div class='produkt__text'><h3 class='produkt__name'>OPTISENS IND 1000 PP IMM<\/h3><p>Water, wastewater and chemical applications for immersion installation<\/p><div class='produkt__features'><ul><li>1\u20262000 mS\/cm; Max. +60\u00b0C \/ +140\u00b0F; 1 bar \/ 14 psi<\/li><li>Inductive conductivity sensor (PP), complete with immersion mounting assembly and Pt1000 <\/li><\/ul><\/div><a href=\"#\" class=\"produkt__button-request avia-button avia-icon_select-yes-right-icon avia-color-theme-color avia-size-medium avia-position-left\" style=\"background-color:#e94d19;\"><span class=\"avia_iconbox_title\">Send your request<\/span><span class=\"avia_button_icon avia_button_icon_right\" aria-hidden=\"true\" data-av_icon=\"\ue875\" data-av_iconfont=\"entypo-fontello\"><\/span><\/a><br><a href=\"https:\/\/krohne.com\/en\/products\/process-analytics\/analytical-sensors-measuring-systems\/conductivity-sensors-measuring-systems\/optisens-ind-1000\/\" target=\"_blank\" class=\"produkt__button-produkt avia-button avia-icon_select-yes-right-icon avia-color-theme-color avia-size-medium avia-position-left\" rel=\"noopener\"><span class=\"avia_iconbox_title\">View product<\/span><span class=\"avia_button_icon avia_button_icon_right\" aria-hidden=\"true\" data-av_icon=\"\ue875\" data-av_iconfont=\"entypo-fontello\"><\/span><\/a><\/div><\/div><\/div><\/li><li class='produkt f8 f9 f10 f11 f12 f13 f15 f16 f19 f22 f23 f24'><div class='produkt__inside'><div><figure class='produkt__bild'><img src='https:\/\/dam.krohne.com\/image\/upload\/c_scale,w_900\/im-single-product\/optisys-ind-8100-triclamp-compact.png' alt='OPTISYS IND 8100'><small class='produkt__zertifikate'><strong class='produkt__label produkt__label--hygienic'>Hygienic (FDA)<\/strong><strong class='produkt__label produkt__label--3a_ehedg'>3A\/EHEDG<\/strong><\/small><\/figure><div class='produkt__text'><h3 class='produkt__name'>OPTISYS IND 8100<\/h3><p>Food and beverage applications<\/p><div class='produkt__features'><ul><li>0.05\u20261000 mS\/cm; Max. +140\u00b0C \/ +285\u00b0F<\/li><li>Hygienic inductive conductivity measuring system (PEEK sensor), robust (IP69K; 3A and EHEDG)<\/li><\/ul><\/div><a href=\"#\" class=\"produkt__button-request avia-button avia-icon_select-yes-right-icon avia-color-theme-color avia-size-medium avia-position-left\" style=\"background-color:#e94d19;\"><span class=\"avia_iconbox_title\">Send your request<\/span><span class=\"avia_button_icon avia_button_icon_right\" aria-hidden=\"true\" data-av_icon=\"\ue875\" data-av_iconfont=\"entypo-fontello\"><\/span><\/a><br><a href=\"https:\/\/krohne.com\/en\/products\/process-analytics\/analytical-sensors-measuring-systems\/conductivity-sensors-measuring-systems\/optisys-ind-8100\/\" target=\"_blank\" class=\"produkt__button-produkt avia-button avia-icon_select-yes-right-icon avia-color-theme-color avia-size-medium avia-position-left\" rel=\"noopener\"><span class=\"avia_iconbox_title\">View product<\/span><span class=\"avia_button_icon avia_button_icon_right\" aria-hidden=\"true\" data-av_icon=\"\ue875\" data-av_iconfont=\"entypo-fontello\"><\/span><\/a><\/div><\/div><\/div><\/li><li class='produkt f9 f10 f11 f15 f19 f22'><div class='produkt__inside'><div><figure class='produkt__bild'><img src='https:\/\/cmp.krohne.com\/analytics\/wp-content\/uploads\/sites\/37\/2021\/06\/analytical-module-for-dissolved-oxygen-or-inductive-conductivity-measurement-solid-steel.png' alt='Water analysis panel \u2013 analytical module for inductive conductivity measurement'><\/figure><div class='produkt__text'><h3 class='produkt__name'>Water analysis panel \u2013 analytical module for inductive conductivity measurement<\/h3><p>Water applications<\/p><div class='produkt__features'><ul><li>1\u20262000 mS\/cm; Max. +50 \u00b0C \/ +122 \u00b0F; 6 bar \/ 87 psi<\/li><li>Measuring system with inductive conductivity sensor, flow cell and MAC 100 transmitter; can be combined with other modules for further parameters<\/li><\/ul><\/div><a href=\"#\" class=\"produkt__button-request avia-button avia-icon_select-yes-right-icon avia-color-theme-color avia-size-medium avia-position-left\" style=\"background-color:#e94d19;\"><span class=\"avia_iconbox_title\">Send your request<\/span><span class=\"avia_button_icon avia_button_icon_right\" aria-hidden=\"true\" data-av_icon=\"\ue875\" data-av_iconfont=\"entypo-fontello\"><\/span><\/a><br><a href=\"https:\/\/krohne.com\/en\/products\/process-analytics\/analytical-sensors-measuring-systems\/multiparameter-measuring-systems\/water-analysis-panel\/\" target=\"_blank\" class=\"produkt__button-produkt avia-button avia-icon_select-yes-right-icon avia-color-theme-color avia-size-medium avia-position-left\" rel=\"noopener\"><span class=\"avia_iconbox_title\">View product<\/span><span class=\"avia_button_icon avia_button_icon_right\" aria-hidden=\"true\" data-av_icon=\"\ue875\" data-av_iconfont=\"entypo-fontello\"><\/span><\/a><\/div><\/div><\/div><\/li><li class='produkt f6 f7 f8 f9 f11 f15 f19 f22'><div class='produkt__inside'><div><figure class='produkt__bild'><img src='https:\/\/cmp.krohne.com\/analytics\/wp-content\/uploads\/sites\/37\/2021\/06\/analytical-module-for-pH-ORP-and-conductivity-measurement-conductive-solid-steel.png' alt='Water analysis panel \u2013 analytical module for conductive conductivity measurement'><\/figure><div class='produkt__text'><h3 class='produkt__name'>Water analysis panel \u2013 analytical module for conductive conductivity measurement<\/h3><p>Water applications<\/p><div class='produkt__features'><ul><li>1\u20262000 \u00b5S; 0,1\u202620 mS\/cm; Max. +50 \u00b0C \/ +122 \u00b0F; 6 bar \/ 87 psi<\/li><li>Measuring system with conductive conductivity sensor, flow cell, valves and MAC 100 transmitter; can be combined with a second flow cell for pH or ORP measurement or with other modules for further parameters<\/li><\/ul><\/div><a href=\"#\" class=\"produkt__button-request avia-button avia-icon_select-yes-right-icon avia-color-theme-color avia-size-medium avia-position-left\" style=\"background-color:#e94d19;\"><span class=\"avia_iconbox_title\">Send your request<\/span><span class=\"avia_button_icon avia_button_icon_right\" aria-hidden=\"true\" data-av_icon=\"\ue875\" data-av_iconfont=\"entypo-fontello\"><\/span><\/a><br><a href=\"https:\/\/krohne.com\/en\/products\/process-analytics\/analytical-sensors-measuring-systems\/multiparameter-measuring-systems\/water-analysis-panel\/\" target=\"_blank\" class=\"produkt__button-produkt avia-button avia-icon_select-yes-right-icon avia-color-theme-color avia-size-medium avia-position-left\" rel=\"noopener\"><span class=\"avia_iconbox_title\">View product<\/span><span class=\"avia_button_icon avia_button_icon_right\" aria-hidden=\"true\" data-av_icon=\"\ue875\" data-av_iconfont=\"entypo-fontello\"><\/span><\/a><\/div><\/div><\/div><\/li><\/ul><\/div><form id=\"form-produktfilter\" action=\"https:\/\/cmp.krohne.com\/analytics\/request\/\" target=\"_blank\" style=\"display:none\" method=\"POST\"><input type=\"hidden\" id=\"produktfilter-produkt\" name=\"produktfilter-produkt\"><input type=\"hidden\" id=\"produktfilter-data\" name=\"produktfilter-data\"><input type=\"submit\"><\/form><\/div>\n<\/div><\/section>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-2271","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/cmp.krohne.com\/analytics\/wp-json\/wp\/v2\/pages\/2271","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cmp.krohne.com\/analytics\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/cmp.krohne.com\/analytics\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/cmp.krohne.com\/analytics\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/cmp.krohne.com\/analytics\/wp-json\/wp\/v2\/comments?post=2271"}],"version-history":[{"count":37,"href":"https:\/\/cmp.krohne.com\/analytics\/wp-json\/wp\/v2\/pages\/2271\/revisions"}],"predecessor-version":[{"id":3056,"href":"https:\/\/cmp.krohne.com\/analytics\/wp-json\/wp\/v2\/pages\/2271\/revisions\/3056"}],"wp:attachment":[{"href":"https:\/\/cmp.krohne.com\/analytics\/wp-json\/wp\/v2\/media?parent=2271"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}